Introduction
The capacitor are non-inductively wound with a metallized polyester film dielectric/electrode encapsulated in flame retardant(UL 94V-0) plastic case(PBT) and epoxy resin and seal.
Used in fans, air-conditioners, refrigerators, Power Systems (UPS), office equipment, mercury lamps, fluorescent lamps and business machines.
Leads Type
A:Terminals(AMP187&250)
S:Tinned copper steel wire radial leads.
W:Soldering terminals.
P:UL 1015 or UL1007 stranded PVC insulation wire.
Specification
◎Base Specification
- IEC60252-1:2001:S3 Used for AC motor application
- Standard(s) for Safety:UL 810 - Capacitors CSA C22.2, No. 190-14 - Capacitors for Power Factor Correction
- JIS C 4908:Used for electrical apparatus
- CNS 4327:Used for electrical apparatus
◎Climate Category: In accordance with IEC60068-2-3
- H=Minimum Limit Temperature: -25℃
- S=Maximum Limit Temperature: +85℃
- F=Humidity Category: Average relative humidity≦75﹪,
95﹪for 30 days per year, continuously;
85﹪for the remaining days, occasionally
◎Rated Voltage: 250, 300, 350, 400, 450 Vac
◎Capacitance Range: 3μ F ~ 50 μF
◎Capacitance Tolerance: U(- 5%~ +10%), J ( ± 5 % ), K (± 10 % )
◎Withstand Voltage:
- Between Terminals: R.V. ×√2× 175% for 1 minuite(VDC)
- Between Terminals and Case: 2× rated voltage +1,000V(1500V Min) for 60s
This test occasional self-healing breakdown is allowed.
◎Dissipation Factor: 0.1﹪at 200V.AC,60Hz and 25℃
◎Insulation Resistance:
- Between Terminals: Insulation resistance:more than 1,000M ohm μF
- Between Terminals and Case: ≧10 MΩ Measured at 100V.AC, 60s. And 25℃